EMC of converters for in terlocking device

Zobrazit minimální záznam

dc.contributor.author Doleček, Radovan
dc.contributor.author Novák, Jaroslav
dc.contributor.author Černý, Ondřej
dc.date.accessioned 2012-01-30T10:54:58Z
dc.date.available 2012-01-30T10:54:58Z
dc.date.issued 2009
dc.identifier.isbn 978-80-7395-364-5
dc.identifier.issn 1211-6610
dc.identifier.uri http://hdl.handle.net/10195/42241
dc.description.abstract The paper deals with problems of electromagnetic compatibility (EMC) of frequency control drive of electromotive switch actuator of railway switch. The frequency converter with Pulse Width Modulation (PWM) and the output sinus filter are used for feeding of the asynchronous motor of the switch actuator. This drive is operated in isolated system of feeding voltages. The drive is fed by frequency converter with unshielded cable. The EMC problems occurring at development and operating of drive are analyzed. The new version of contactless safe switch, which works without PWM, is presented at the end of this paper. cze
dc.format p. 61-67
dc.language.iso eng
dc.publisher Univerzita Pardubice cze
dc.relation.ispartof Scientific papers of the University of Pardubice. Series B, Jan Perner Transport Faculty. 15 (2009)
dc.subject EMC cze
dc.subject interlocking device cze
dc.subject electromotive switch actuator cze
dc.title EMC of converters for in terlocking device cze
dc.type Article cze
dc.identifier.signature 47578-15
dc.peerreviewed yes
dc.publicationstatus published


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Vyhledávání


Rozšířené hledání

Procházet

Můj účet