Strengthening of substandard reinforced concrete beam-column joints by external post-tension rods

ČlánekOmezený přístuppeer-reviewedpublished version
dc.contributor.authorYurdakul, Özgürcze
dc.contributor.authorAvsar, Ozgurcze
dc.date.accessioned2017-05-11T11:19:26Z
dc.date.available2017-05-11T11:19:26Z
dc.date.issued2016eng
dc.description.abstractThe efficiency of the proposed strengthening method using externally applied post-tension rods in reinforced concrete external beam-column joints, which do not comply with any code requirements, is investigated. Five full-scale specimens were tested in the laboratory. They have specific deficiencies resulting from the lack of shear reinforcement in the joint and poor material properties including low strength concrete and the presence of plain round reinforcement bars. While all specimens were built with column and in plane beam, one of the tested specimens consists of a transverse beam to demonstrate the applicability of the presented retrofit technique. All specimens were subjected to a cyclic quasi-static loading up to 8% drift ratio to observe different levels of structural damage. Two post-tension rods, which were mounted diagonally at each side of the joint, are utilized as a local retrofit technique. The reference specimen displayed a brittle behavior with the concentration of shear cracks mostly in the joint while the rest of the RC components were almost in their elastic range. The ultimate lateral load capacity was increased considerably for all retrofitted specimens. However, a brittle type of failure mechanism was observed such as a joint shear failure or beam-joint failure in the three retrofitted specimens. A relatively ductile response was observed in the specimen with transverse beam, although the axial force in the post-tension rods was the same with the specimens without transverse beam. After testing all specimens, it is found that the lateral force capacities of the beam-column assemblies can be improved up to code requirements by the proposed retrofitting method.eng
dc.description.abstract-translatedThe efficiency of the proposed strengthening method using externally applied post-tension rods in reinforced concrete external beam-column joints, which do not comply with any code requirements, is investigated. Five full-scale specimens were tested in the laboratory. They have specific deficiencies resulting from the lack of shear reinforcement in the joint and poor material properties including low strength concrete and the presence of plain round reinforcement bars. While all specimens were built with column and in plane beam, one of the tested specimens consists of a transverse beam to demonstrate the applicability of the presented retrofit technique. All specimens were subjected to a cyclic quasi-static loading up to 8% drift ratio to observe different levels of structural damage. Two post-tension rods, which were mounted diagonally at each side of the joint, are utilized as a local retrofit technique. The reference specimen displayed a brittle behavior with the concentration of shear cracks mostly in the joint while the rest of the RC components were almost in their elastic range. The ultimate lateral load capacity was increased considerably for all retrofitted specimens. However, a brittle type of failure mechanism was observed such as a joint shear failure or beam-joint failure in the three retrofitted specimens. A relatively ductile response was observed in the specimen with transverse beam, although the axial force in the post-tension rods was the same with the specimens without transverse beam. After testing all specimens, it is found that the lateral force capacities of the beam-column assemblies can be improved up to code requirements by the proposed retrofitting method.cze
dc.formatp. 9-22eng
dc.identifier.doi10.1016/j.engstruct.2015.11.004eng
dc.identifier.issn0141-0296eng
dc.identifier.obd39878053eng
dc.identifier.scopus2-s2.0-84947050925
dc.identifier.urihttps://hdl.handle.net/10195/67700
dc.identifier.wos000366775600002
dc.language.isoengeng
dc.peerreviewedyeseng
dc.publicationstatuspublished versioneng
dc.publisherElsevier Scienceeng
dc.relation.ispartofEngineering Structures, volume 107, issue: 15.1.2016eng
dc.rightspráce není přístupnáeng
dc.subjectPost-tensioneng
dc.subjectBeam-column jointeng
dc.subjectRetrofiteng
dc.subjectLow strength concreteeng
dc.subjectPlain bareng
dc.subjectShear failureeng
dc.subjectCyclic loadingeng
dc.subjectPost-tensioncze
dc.subjectBeam-column jointcze
dc.subjectRetrofitcze
dc.subjectLow strength concretecze
dc.subjectPlain barcze
dc.subjectShear failurecze
dc.subjectCyclic loadingcze
dc.titleStrengthening of substandard reinforced concrete beam-column joints by external post-tension rodseng
dc.title.alternativeStrengthening of substandard reinforced concrete beam-column joints by external post-tension rodscze
dc.typeArticleeng
dspace.entity.typePublication

Soubory

Původní svazek

Nyní se zobrazuje 1 - 1 z 1
Načítá se...
Náhled
Název:
1-s2.0-S0141029615006987-main.pdf
Velikost:
3.05 MB
Formát:
Adobe Portable Document Format