Digitální knihovnaUPCE
 

Design a combination of filters to reduce decline the attenuation in magnitude response

Článekpeer-reviewedpostprint
Náhled

Datum publikování

2019

Vedoucí práce

Oponent

Název časopisu

Název svazku

Vydavatel

WSEAS Press

Abstrakt

Some biquad filters structures are characterized by a decreasing of the attenuation at high frequencies, caused by the final value of the output resistance of the operational amplifier. This decreasing of the attenuation occurs only for the some even orders filters, i.e. for the biquads, of which a higher order filter is composed. One possible solution is to replace the biquad with another biquad that does not have this property. The conversion of parameters of such biquads to each other biquad is described in the detailed steps. The results of the proposed numerical procedure are verified by simulation.

Rozsah stran

p. 90-95

ISSN

1109-2734

Trvalý odkaz na tento záznam

Projekt

Zdrojový dokument

Wseas transaction on circuits and systems, volume 18, issue: 2019

Vydavatelská verze

http://www.wseas.org/multimedia/journals/circuits/2019/a305101-084.pdf

Přístup k e-verzi

open access

Název akce

ISBN

Studijní obor

Studijní program

Signatura tištěné verze

Umístění tištěné verze

Přístup k tištěné verzi

Klíčová slova

biquad, low path filter, structure SK, structure H, higher order filter, magnitude response, bikvad, dolní propust, struktura SK, struktura H, vyšší řád filtru, útlumová charakteristika

Endorsement

Review

item.page.supplemented

item.page.referenced