Design a combination of filters to reduce decline the attenuation in magnitude response
Článekpeer-reviewedpostprintSoubory
Datum publikování
2019
Autoři
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
WSEAS Press
Abstrakt
Some biquad filters structures are characterized by a decreasing of the attenuation at high frequencies, caused by the final value of the output resistance of the operational amplifier. This decreasing of the attenuation occurs only for the some even orders filters, i.e. for the biquads, of which a higher order filter is composed. One possible solution is to replace the biquad with another biquad that does not have this property. The conversion of parameters of such biquads to each other biquad is described in the detailed steps. The results of the proposed numerical procedure are verified by simulation.
Rozsah stran
p. 90-95
ISSN
1109-2734
Trvalý odkaz na tento záznam
Projekt
Zdrojový dokument
Wseas transaction on circuits and systems, volume 18, issue: 2019
Vydavatelská verze
http://www.wseas.org/multimedia/journals/circuits/2019/a305101-084.pdf
Přístup k e-verzi
open access
Název akce
ISBN
Studijní obor
Studijní program
Signatura tištěné verze
Umístění tištěné verze
Přístup k tištěné verzi
Klíčová slova
biquad, low path filter, structure SK, structure H, higher order filter, magnitude response, bikvad, dolní propust, struktura SK, struktura H, vyšší řád filtru, útlumová charakteristika