dc.contributor.author |
Jeličová, Marcela
|
cze |
dc.contributor.author |
Metelka, Radovan
|
cze |
dc.contributor.author |
Pejchal, Jaroslav
|
cze |
dc.contributor.author |
Lierová, Anna
|
cze |
dc.contributor.author |
Šinkorová, Zuzana
|
cze |
dc.date.accessioned |
2020-03-19T13:03:02Z |
|
dc.date.available |
2020-03-19T13:03:02Z |
|
dc.date.issued |
2019 |
eng |
dc.identifier.issn |
0026-9247 |
eng |
dc.identifier.uri |
https://hdl.handle.net/10195/75009 |
|
dc.description.abstract |
The paper presents the findings of an optimization and validation results of electrochemical detection of 8-hydroxyguanine, a major marker of oxidative stress, using disposable screen-printed carbon electrode (SPCE) modified with carboxy-functionalized multi-walled carbon nanotubes (MWCNTs-COOH). Several types of bare and modified SPCEs were tested and modification with MWCNTs-COOH was found superior in terms of measured current response, level of background currents, and sensitivity in oxidation of 8-hydroxyguanine. The effect of pH and composition of supporting electrolyte on current response and peak potential were also evaluated. Validation parameters were calculated for optimum pH 7 of 0.01moldm(-3) phosphate buffer. The sensor showed the highest sensitivity of 0.0625 mu A dm(3) mu mol(-1) within the linear range 0.3-12 mu moldm(-3) with a limit of detection as low as 0.57 mu moldm(-3). Extended linear range 0.3-240 mu moldm(-3) is feasible with a sensitivity of 0.0523 mu A dm(3) mu mol(-1). Intra-day and inter-day assays within 3days were performed to verify the repeatability of modified screen-printed carbon sensors. Finally, the sensor was utilized for electrochemical monitoring of stability of 8-hydroxyguanine when stored in room temperature, in the refrigerator, or frozen and thawed. [GRAPHICS] . |
eng |
dc.format |
p. 1187-1193 |
eng |
dc.language.iso |
eng |
eng |
dc.publisher |
Springer |
eng |
dc.relation.ispartof |
Monatshefte fur Chemie, volume 150, issue: 7 |
eng |
dc.rights |
pouze v rámci univerzity |
cze |
dc.subject |
8-Hydroxyguanine |
eng |
dc.subject |
Screen-printed carbon electrode |
eng |
dc.subject |
Multi-walled carbon nanotubes |
eng |
dc.subject |
Differential pulse voltammetry |
eng |
dc.subject |
8-Hydroxyguanin |
cze |
dc.subject |
Uhlíková tištěná elektroda |
cze |
dc.subject |
Vícestěnné uhlíkové nanotrubičky |
cze |
dc.subject |
Diferenční pulzní voltametrie |
cze |
dc.title |
Electrochemical detection of 8-hydroxyguanine using screen-printed carbon electrodes modified with carboxy-functionalized multi-walled carbon nanotubes |
eng |
dc.title.alternative |
Elektrochemická detekce 8-hydroxyguaninu s použitím uhlíkových tištěných elektrod modifikovaných vícestěnnými uhlíkovými naotrubičkami s karboxy skupinami |
cze |
dc.type |
article |
eng |
dc.description.abstract-translated |
Práce předkládá výsledky optimalizace a validace elektrochemické detekce 8-hydroxyguaninu, hlavního markeru oxidativního stresu, s využitím jednorázové uhlíkové tištěné elektrody (SPCE) modifikované vícestěnnými uhlíkovými nanotrubičkami s karboxy skupinami (MWCNTs-COOH). Bylo testováno několik typů SPCE a modifikace s MWCNTs-COOH vykazovala nejlepší charakteristiky při elektrochemické detekci 8-hydroxyguaninu. Validace byla provedena v 0,01 M fosfátovém pufru při optimálním pH 7. Citlivost stanovení byla 0,0625 mu A dm(3) mu mol(-1), lineární rozsah 0,3 - 12 mu moldm(-3) a detekční limit 0,57 mu moldm(-3). Je možné použít rozšířený lineární rozsah 0,3 - 240 mu moldm(-3) s citlivostí 0,0523 mu A dm(3) mu mol(-1). Byly provedeny intra-day a inter-day analýzy v rozmezí tří dní k verifikaci opakovatelnosti modifikovaného SPCE senzoru. Závěrem byl senzor použit k elektrochemickému monitorování stability 8-hydroxyguaninu při skladování jeho roztoků při pokojové teplotě, v lednici a při zmražování a rozmrazování. |
cze |
dc.peerreviewed |
yes |
eng |
dc.publicationstatus |
published version |
eng |
dc.identifier.doi |
10.1007/s00706-019-02433-3 |
eng |
dc.relation.publisherversion |
https://link.springer.com/article/10.1007/s00706-019-02433-3 |
eng |
dc.identifier.wos |
000475674200003 |
eng |
dc.identifier.obd |
39883579 |
eng |