Adsorptive stripping voltammetry of vitamin D3 at glassy carbon electrode
ČlánekOtevřený přístuppeer-reviewedpublishedDatum publikování
2018
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
University of Pardubice
Abstrakt
Adsorptive stripping voltammetry (AdSV) of cholecalciferol at the glassy carbon
electrode (GCE) was developed and based on existing conventional approaches
employing anodic oxidation in pure organic electrolytes or aqueous-organic mixtures.
Despite a rather poor reproducibility of the adsorption-driven process (with the RSD of
ca. 10 %), significantly higher sensitivity was achieved. As optimum conditions, the
respective procedure comprised an accumulation of cholecalciferol from 40% ethanol
at 300 min–1 for 8 min followed by electrochemical detection in the Britton-Robinson
buffer (pH 4.0) using square-wave voltammetry at a potential step of 5 mV, amplitude
of 35 mV, and frequency of 40 Hz
Rozsah stran
p. 21 - 30
ISSN
1211-5541
Trvalý odkaz na tento záznam
Projekt
Zdrojový dokument
Scientific papers of the University of Pardubice. Series A, Faculty of Chemical Technology. 24/2018
Vydavatelská verze
Přístup k e-verzi
open access
Název akce
ISBN
978-80-7560-167-4
Studijní obor
Studijní program
Signatura tištěné verze
Umístění tištěné verze
Přístup k tištěné verzi
Klíčová slova
adsorption, glassy carbon electrode, square-wave voltammetry, vitamin D3