Voltammetric Behavior of the Insecticide Pymetrozine on a Mercury Meniscus Modified Silver Solid Amalgam Electrode

Zobrazit minimální záznam

dc.contributor.author Šelešovská, Renáta cze
dc.contributor.author Janíková, Lenka cze
dc.contributor.author Kadubcová, Michaela cze
dc.contributor.author Štěpánková, Michaela cze
dc.date.accessioned 2017-05-11T11:05:44Z
dc.date.available 2017-05-11T11:05:44Z
dc.date.issued 2016 eng
dc.identifier.issn 0003-2719 eng
dc.identifier.uri http://hdl.handle.net/10195/67531
dc.description.abstract A novel sensitive voltammetric method for the determination of the insecticide pymetrozine was designed using a solid working electrode. A mercury meniscus modified silver solid amalgam electrode in connection with differential pulse voltammetry was found to be appropriate for the determination of the insecticide. Pymetrozine provided one well-developed reduction peak suitable for analytical purposes at approximately −800 millivolts (vs. the Ag/AgCl electrode) in an acidic medium. The voltammetric behavior of pymetrozine as a function of the pH of the supporting electrolyte and scan rate was investigated using cyclic voltammetry and direct current voltammetry, respectively. The optimum conditions for determination using differential pulse voltammetry were in a Britton-Robinson buffer at pH 3.0 with a limit of detection of 5.4 × 10−8 moles per liter and a linear dynamic range from 2 × 10−7 to 1 × 10−4 moles per liter. The relative standard deviations of repeated determinations (n = 5) at various concentrations of pymetrozine did not exceed 3%. The results obtained using a silver solid amalgam electrode were compared with those achieved on hanging mercury drop electrode. The influence of possible interfering agents was also studied. The practical application of the method was verified by analysis of pesticide preparations and fortified river water. eng
dc.format p. 4-18 eng
dc.language.iso eng eng
dc.relation.ispartof Analytical Letters, volume 49, issue: 1 eng
dc.rights práce není přístupná eng
dc.subject Hanging mercury drop electrode eng
dc.subject insecticide eng
dc.subject mercury meniscus modified silver solid amalgam electrode eng
dc.subject pymetrozine eng
dc.subject voltammetry eng
dc.subject Visící rtuťová kapková elektroda cze
dc.subject insekticid cze
dc.subject rtuťovým meniskem modifikovaná stříbrná pevná amalgámová elektroda cze
dc.subject pymetrozin cze
dc.subject voltametrie cze
dc.title Voltammetric Behavior of the Insecticide Pymetrozine on a Mercury Meniscus Modified Silver Solid Amalgam Electrode eng
dc.title.alternative Voltametrické chování insekticidu pymetrozinu na rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrodě cze
dc.type article eng
dc.description.abstract-translated V rámci práce bylo studováno voltametrické chování insekticidu pymetrozinu na rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrodě v závislosti na pH a rychlosti polarizace. Poté byla vyvinuta metoda stanovení pymetrozinu, která byla aplikována při analýze přírodních vod a insekticidního přípravku. cze
dc.peerreviewed yes eng
dc.publicationstatus published version eng
dc.identifier.doi 10.1080/00032719.2014.979293 eng
dc.identifier.wos 000363048900002 eng
dc.identifier.scopus 2-s2.0-84944916728
dc.identifier.obd 39876953 eng