Digitální knihovnaUPCE
 

The Adjoint Transformation Usage for Correction of the Attenuation of the Low-pass Biquad in the Current Mode

Konferenční objektpeer-reviewedpostprint
Náhled není k dispozici

Datum publikování

2016

Vedoucí práce

Oponent

Název časopisu

Název svazku

Vydavatel

IEEE (Institute of Electrical and Electronics Engineers)

Abstrakt

The second order Sallen-Key low-pass filter structures (so called biquads) in the voltage and current mode have one common disadvantage, it is a decreasing of the attenuation in the stopband. This fact is caused by losses of the amplification factor of active elements at high frequencies. Some solutions of this problem had been already published for circuits working in the voltage mode, but this problem was not satisfactorily solved for circuits working in the current mode. Therefore, this article presents one of the possible solutions of this problem for circuits working in the current mode.

Rozsah stran

p. 48-50

ISSN

Trvalý odkaz na tento záznam

Projekt

SGS_2016_022/Výzkum zpracování rádiových a multimediálních signálů

Zdrojový dokument

Radioelektronika 2016 : conference proceedings

Vydavatelská verze

Přístup k e-verzi

Pouze v rámci univerzity

Název akce

26th International Conference on Radioelektronika (RADIOELEKTRONIKA) (19.04.2016 - 20.04.2016)

ISBN

978-1-5090-1674-7

Studijní obor

Studijní program

Signatura tištěné verze

Umístění tištěné verze

Přístup k tištěné verzi

Klíčová slova

Current mode, voltage mode, adjoint transformation, biquad, low pass filter, Sallen-Key structure