Comparison of heat capacity of solid explosives by DSC and group contribution methods
ČlánekOmezený přístuppeer-reviewedpostprintDatum publikování
2015
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
Springer
Abstrakt
The isobaric heat capacities of solid explosive materials were measured using differential scanning calorimeter. The values of C-p were determined at temperature 298.15 K and compared to theoretical data calculated using the group additivity approach. Several group contribution methods were tested, showing that certain method for some explosives provides estimation of C-p with error only 1 %. Generally, the average error limit for calculated C-p was about 11 %, which is insufficient.
Rozsah stran
p. 683-689
ISSN
1388-6150
Trvalý odkaz na tento záznam
Projekt
VG20102014032/Výzkum detekce improvizovaných výbušnin psy
Zdrojový dokument
Journal of Thermal Analysis and Calorimetry, volume 121, issue: 2
Vydavatelská verze
Přístup k e-verzi
Práce není přístupná
Název akce
ISBN
Studijní obor
Studijní program
Signatura tištěné verze
Umístění tištěné verze
Přístup k tištěné verzi
Klíčová slova
Explosive material, Isobaric heat capacity, Differential scanning calorimetry, Modified stepwise method, Group contribution method, výbušný materiál, izobarická tepelná kapacita, diferenciální skenovací kategorie, modifikovaná skoková metoda, příspěvková metoda