Publikace: Characterization and optimalization of electrostatic discharge (ESD) sensitiveness of potassium 4,6-dinitrobenzofuroxane
Konferenční objektopen accesspeer-reviewedpublishedNačítá se...
Datum
Autoři
Zahálka, Martin
Pelikán, Vojtěch
Matyáš, Robert
Název časopisu
ISSN časopisu
Název svazku
Nakladatel
Univerzita Pardubice
Abstrakt
It was found that the electrostatic discharge sensitivity of potassium 4,6-dinitrobenzofuroxane (KDNBF) have risky value of minimal initiation energy (MIE) value. The lowest measured energy was within the range of 30 mikroJ. Additions of conductive graphite to KDNBF didn’t changed MIE level significantly. Efforts has been made to find way how the graphite addition influence ESD sensitiveness in form of threshold initiation level and probability of sample initiation. It was found that the MIE values remains still but conductive admixtures influenced the probabilities of initiation. The highest measured energy without initiation of sample changed with the content of graphite. Influence of ultrasonic homogenizers on MIE levels was studied.
Popis
Klíčová slova
ESD, KDNBF, potassium 4,6-dinitrobenzofuroxane, ESD, KDNBF, draselná sůl 4,6-dinitrobenzofuroxanu