Publication: Surface functionalization of a chalcogenide IR photonic sensor by means of a polymer membrane for water pollution remediation
Articleaccess-status.open.listelement.badgepeer-reviewedpublishedLoading...
Files
Date
Thesis advisor
Referee
Journal Title
Journal ISSN
Volume Title
Publisher
Royal Society of Chemistry
Abstract
Rapid, simultaneous detection of organic chemical pollutants in water is an important issue to solve for protecting human health. This study investigated the possibility of developing an in situ reusable optical sensor capable of selective measurements utilizing a chalcogenide transducer supplemented by a hydrophobic polymer membrane with detection based on evanescent waves in the mid-infrared spectrum. In order to optimise a polyisobutylene hydrophobic film deposited on a chalcogenide waveguide, a zinc selenide prism was utilized as a testbed for performing attenuated total reflection with Fourier-transform infrared spectroscopy. To comply with the levels mentioned in health guidelines, the target detection range in this study was kept rather low, with the concentration range extended from 50 ppb to 100 ppm to cover accidental pollution problems, while targeted hydrocarbons (benzene, toluene, and xylene) were still detected at a concentration of 100 ppb. Infrared measurements in the selected range showed a linear behaviour, with the exception of two constantly reproducible plateau phases around 25 and 80 ppm, which were observable for two polymer film thicknesses of 5 and 10 mu m. The polymer was also found to be reusable by regenerating it with water between individual measurements by increasing the water temperature and flow to facilitate reverse exchange kinetics. Given the good conformability of the hydrophobic polymer when coated on chalcogenide photonic circuits and its demonstrated ability to detect organic pollutants in water and to be regenerated afterwards, a microfluidic channel utilising water flow over an evanescent wave optical transducer based on a chalcogenide waveguide and a polyisobutylene (PIB) hydrophobic layer deposited on its surface was successfully fabricated from polydimethylsiloxane by filling a mold prepared via CAD and 3D printing techniques. Optimisation of the functionalisation of infrared chalcogenide sensors for accidental water pollution using a hydrophobic polymer.
Description
Pages
p. 4723-4735
ISSN
0003-2654
Project
GA22-05179S/Infračervená fotonika pro chemické senzory: Materiálová strategie založená na amorfních chalkogenidech
Is Part of
Analyst, volume 149, issue: 18
Publisher Version
Related Resources
E-version Access
open access
Conference Name
ISBN
Study Specialization
Study Programme
Library Call Number
Printed Version Location
Printed Version Access Rights
Keywords
organic pollutants, hydrocarbons, spectroscopy, temperature, detekce BTX, FTIR, ATR
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as open access
