Zobrazit minimální záznam
dc.contributor.author |
Mackova, A
|
cze |
dc.contributor.author |
Jagerova, A
|
cze |
dc.contributor.author |
Lalik, O
|
cze |
dc.contributor.author |
Miksova, R
|
cze |
dc.contributor.author |
Poustka, D
|
cze |
dc.contributor.author |
Mistrík, Jan
|
cze |
dc.contributor.author |
Holy, V
|
cze |
dc.contributor.author |
Schutter, J. D
|
cze |
dc.contributor.author |
Kentsch, U
|
cze |
dc.contributor.author |
Marvan, P
|
cze |
dc.contributor.author |
Azarov, A
|
cze |
dc.contributor.author |
Galeckas, A
|
cze |
dc.date.accessioned |
2024-08-24T07:24:04Z |
|
dc.date.available |
2024-08-24T07:24:04Z |
|
dc.date.issued |
2023 |
eng |
dc.identifier.issn |
0169-4332 |
eng |
dc.identifier.uri |
https://hdl.handle.net/10195/83756 |
|
dc.description.abstract |
ZnO nanopillars were implanted with Au-400 keV and Ag-252 keV ions with ion fluences from 1 x 1015 cm-2 to 1 x 1016 cm-2. We compared ZnO nanopillars solely implanted with Au-ions and dually-implanted with Au and Ag-ions. Rutherford Back-Scattering spectrometry (RBS) confirmed Ag and Au embedded in ZnO nanopillar layers in a reasonable agreement with theoretical calculations. A decreasing thickness of the ZnO nanopillar layer was evidenced with the increasing ion implantation fluences. Spectroscopic Ellipsometry (SE) showed a decrease of refractive index in the nanopillar parts with embedded Au, Ag-ions. XRD discovered vertical domain size decreasing with the proceeding radiation damage accumulated in ZnO nanopillars which effect was preferably ascribed to Au-ions. SE and diffuse reflectance spectroscopy (DRS) showed optical activity of the created nanoparticles at wavelength range 500 - 600 nm and 430 - 700 nm for the Au-implanted and Au, Ag-implanted ZnO nanopillars, respectively. Photoluminescence (PL) features linked to ZnO deep level emission appear sub-stantially enhanced due to plasmonic interaction with metal nanoparticles created by Ag, Au-implantation. Photocatalytic activity seems to be more influenced by the nanoparticles presented in the layer rather than the surface morphology. Dual implantation with Ag, Au-ions enhanced optical activity to a larger extent without significant morphology deterioration as compared to the solely Au-ion implanted nanopillars. |
eng |
dc.format |
p. 155556 |
eng |
dc.language.iso |
eng |
eng |
dc.publisher |
Elsevier Science BV |
eng |
dc.relation.ispartof |
Applied Surface Science, volume 610, issue: February |
eng |
dc.rights |
Práce není přístupná |
eng |
dc.subject |
ZnO nanopillars |
eng |
dc.subject |
Au |
eng |
dc.subject |
Ag nanoparticles ion implantation |
eng |
dc.subject |
SPR |
eng |
dc.subject |
doped ZnO nanostructures |
eng |
dc.subject |
ZnO nanopilíře |
cze |
dc.subject |
Iontová implantace |
cze |
dc.subject |
Au a Ag nanočástice |
cze |
dc.subject |
SPR |
cze |
dc.subject |
dopované nanostruktury |
cze |
dc.subject |
ZnO |
cze |
dc.title |
Combined Au/Ag nanoparticle creation in ZnO nanopillars by ion implantation for optical response modulation and photocatalysis |
eng |
dc.title.alternative |
Kombinovaná tvorba nanočástic Au/Ag v ZnO nanopilířích pomocí implantace iontů pro modulaci optické odezvy a fotokatalýzu |
cze |
dc.type |
article |
eng |
dc.description.abstract-translated |
Do nanopilířů ZnO byly implantovány ionty Au-400 keV a Ag-252 keV s fluencemi iontů od 1 x 10^15 cm-2 do 1 x 10^16 cm-2. Rutherfordova zpětná rozptylová spektrometrie (RBS) potvrdila Ag a Au zasazené do nanopilárních vrstev ZnO v rozumné shodě s teoretickými výpočty. S rostoucími vlivy implantace iontů byla prokázána zmenšující se tloušťka nanopilární vrstvy ZnO. Spektroskopická elipsometrie (SE) ukázala pokles indexu lomu v nanopilárních částech s vloženými Au, Ag-ionty. XRD objevila zmenšující se velikost vertikální domény s postupujícím radiačním poškozením akumulovaným v nanopilárech ZnO, přičemž tento efekt byl přednostně připisován Au-iontům. SE a difuzní reflektanční spektroskopie (DRS) prokázaly optickou aktivitu vytvořených nanočástic v rozsahu vlnových délek 500 - 600 nm a 430 - 700 nm pro nanopiláry ZnO implantované Au a Au, Ag. Vlastnosti fotoluminiscence (PL) spojené s hloubkovou emisí ZnO se zdají být podstatně vylepšeny díky plasmonické interakci s kovovými nanočásticemi vytvořenými Ag, Au-implantací. Zdá se, že fotokatalytická aktivita je více ovlivněna nanočásticemi přítomnými ve vrstvě než morfologií povrchu. Dvojitá implantace s Ag, Au-ionty zvýšila optickou aktivitu ve větší míře bez výrazného zhoršení morfologie ve srovnání s nanoplíři implantovanými výhradně Au-ionty. |
cze |
dc.peerreviewed |
yes |
eng |
dc.publicationstatus |
postprint |
eng |
dc.identifier.doi |
10.1016/j.apsusc.2022.155556 |
eng |
dc.relation.publisherversion |
https://www.sciencedirect.com/science/article/pii/S0169433222030847?via=ihub |
eng |
dc.project.ID |
90103/CEMNAT II |
eng |
dc.identifier.wos |
000892946400004 |
eng |
dc.identifier.scopus |
2-s2.0-85141444893 |
eng |
dc.identifier.obd |
39889306 |
eng |
Tento záznam se objevuje v následujících kolekcích
Zobrazit minimální záznam
|
Vyhledávání
Procházet
-
Vše v Digitální knihovně
-
Tato kolekce
Můj účet
|