The effect of feed pretreatment on membrane microfiltration of titanium dioxide dispersions by ceramic tubular membranes

Zobrazit minimální záznam

dc.contributor.author Grulich, Miroslav cze
dc.contributor.author Mikulášek, Petr cze
dc.date.accessioned 2017-05-11T11:13:54Z
dc.date.available 2017-05-11T11:13:54Z
dc.date.issued 2016 eng
dc.identifier.issn 1944-3994 eng
dc.identifier.uri http://hdl.handle.net/10195/67630
dc.description.abstract The influence of coagulant type and operating parameters on crossflow microfiltration of aqueous dispersions of titanium dioxide has been examined. The experiments were carried out with a tubular ceramic microfiltration membrane with a nominal pore size of 0.1m at various operating parameters. Three chosen types of organic coagulants were used for a series of crossflow microfiltration experiments: polyacrylamide (PAM), poly(diallyldimethylammonium chloride) (PDADMAC), and poly(acrylamide-co-acrylic acid) partial sodium salt (PACA). The results of the experiments without coagulants showed that the flux initially declines rapidly and then stabilizes. The results also suggested that PDADMAC was a better coagulant for this system and its optimal concentration was 30mgl(-1). Finally, it was shown that pretreatment of the feed by PDADMAC resulted in a permeate flux that was more than three times higher than that obtained without any pretreatment. Moreover, there was a very positive effect of this coagulant on the particle size. Pretreatment by 30mgl(-1) PDADMAC led to an average particle size that was almost 18 times higher than that obtained without pretreatment. The other two coagulants did not produce such improvements: pretreatment of the feed by PAM increased the permeate flux by only 10%, while pretreatment by PACA gave even lower permeate flux than no pretreatment. This means that the results of various experiments have shown the need for careful selection of the coagulant due to their differing influences on the permeate flux. The relationship between the particle size of the dispersion and the permeate flux was found from the results of these experiments. A published mathematical model was used to estimate the permeate flux. The results of the experiments showed that the mathematical model was able to predict the steady-state permeate flux quite accurately in some cases. eng
dc.format p. 23246-23256 eng
dc.language.iso eng eng
dc.relation.ispartof Desalination and Water Treatment, volume 57, issue: 48-49 eng
dc.rights práce není přístupná eng
dc.subject microfiltration eng
dc.subject titanium dioxide dispersions eng
dc.subject ceramic tubular membranes eng
dc.subject mikrofiltrace cze
dc.subject disperze oxidu titaničitého cze
dc.subject keramické trubkové membrány cze
dc.title The effect of feed pretreatment on membrane microfiltration of titanium dioxide dispersions by ceramic tubular membranes eng
dc.title.alternative Vliv předúpravy nástřiku na membránovou mikrofiltraci disperzí oxidu titaničitého pomocí keramických trubkových membrán cze
dc.type article eng
dc.description.abstract-translated Příspěvek se zabývá vlivem typu koagulantu a provozních parametrů na crossflow mikrofiltraci vodných disperzí oxidu titaničitého. Experimenty byly prováděny s mikrofiltrační trubkovou keramickou membránou se střední velikostí pórů 0,1 um při různých provozních parametrech. Byly použity tři vybrané typy organického koagulantu pro řadu mikrofiltračních experimentů. Experimentální výsledky ukazují, že je třeba pečlivý výběr koagulantů, protože různé typy koagulantů mají různý vliv na výkon mikrofiltrace, tj. na intenzitu toku permeátu. Na základě experimentů byl nalezen vztah mezi velikostí částic disperze a intenzitou toku permeátu. cze
dc.peerreviewed yes eng
dc.publicationstatus published version eng
dc.identifier.doi 10.1080/19443994.2016.1144762