dc.contributor.advisor |
Urban, Jiří |
cze |
dc.contributor.author |
Komendová, Martina
|
|
dc.date.accessioned |
2015-08-10T07:51:23Z |
|
dc.date.available |
2015-08-10T07:51:23Z |
|
dc.date.issued |
2015 |
|
dc.identifier |
Univerzitní knihovna (studovna) |
cze |
dc.identifier.uri |
http://hdl.handle.net/10195/60636 |
|
dc.description.abstract |
Tato diplomova prace se zabyva připravou monolitickych kapilarnich kolon s uhlikovymi mikroelektrodami. Pomoci uhlikovych a střibrnych mikrovlaken byla vytvořena pracovni a referentni elektroda, ktere byly nasledn. fixovany uvnitř křemenne kapilary s vnitřnim průměrem 530 mikro m. Vlastnosti připraveneho elektrochemickeho detektoru byly optimalizovany z hlediska stability, linearity stanoveni a meze detekce. Mikroelektrodovy elektrochemicky detektor byl použit pro chromatografickou analyzu neurotransmiterů. |
cze |
dc.format |
67 s. |
cze |
dc.format.extent |
2798129 bytes |
cze |
dc.format.mimetype |
application/pdf |
cze |
dc.language.iso |
cze |
|
dc.publisher |
Univerzita Pardubice |
cze |
dc.rights |
Práce není přístupná |
cze |
dc.subject |
capillary liquid chromatography |
cze |
dc.subject |
carbon microfibers |
cze |
dc.subject |
electrochemical detection |
cze |
dc.subject |
monolithic stationary phases |
cze |
dc.subject |
neurotransmitters |
cze |
dc.subject |
elektrochemická detekce |
cze |
dc.subject |
kapilární kapalinová chromatografie |
cze |
dc.subject |
monolitické stacionární fáze |
cze |
dc.subject |
neurotransmitery |
cze |
dc.subject |
uhlíková vlákna |
cze |
dc.title |
Příprava monolitických kapilárních kolon s uhlíkovými mikroelektrodami |
cze |
dc.title.alternative |
Development of a monolithic capillary columns with carbon microelectrodes |
eng |
dc.type |
diplomová práce |
cze |
dc.contributor.referee |
Bartoš, Martin |
cze |
dc.date.accepted |
2015 |
cze |
dc.description.abstract-translated |
The aim of this work is to prepare an integrated electrochemical detector inside fused-silica capillary with monolithic stationary phase. To reach this goal, we have used carbon and silver microfibers and used them as a working and reference electrode, respectively. After their integration inside the capillary, the preparation of presented electrochemical detector has been optimized in terms of stability, linearity and limits of detection. Finally, microelectrode capillary detector was used for chromatographic analysis of neurotransmitters. |
eng |
dc.description.department |
Katedra analytické chemie |
cze |
dc.thesis.degree-discipline |
Analytická chemie |
cze |
dc.thesis.degree-name |
Ing. |
cze |
dc.thesis.degree-grantor |
Univerzita Pardubice. Fakulta chemicko-technologická |
cze |
dc.identifier.signature |
D33436 |
cze |
dc.thesis.degree-program |
Chemie |
cze |
dc.description.defence |
Přistoupila k obhajobě diplomové práce a zodpověděla vaechny tázané otázky. |
cze |
dc.identifier.stag |
27117 |
cze |
dc.date.embargo |
2035-05-20 |
cze |
dc.description.grade |
Dokončená práce s úspěšnou obhajobou |
cze |