Digitální knihovnaUPCE
 

Voltammetric determination of Diazepam at meniscus-modified silver solid amalgam electrode

ČlánekOtevřený přístuppeer-reviewedpublished
Náhled

Datum publikování

2014

Vedoucí práce

Oponent

Název časopisu

Název svazku

Vydavatel

Univerzita Pardubice

Abstrakt

Voltammetric methods for determination of Diazepam (DZ) were developed. Techniques differential pulse voltammetry and DC voltammetry were used for determination of DZ at meniscus-modified silver solid amalgam electrode (m-AgSAE). The effect of the pH on the intensity of signal of DZ was studied in a mixture of Britton-Robinson buffer + methanol (9:1) and 0.1 M NaOH + methanol (9:1); the optimal medium for analysis was a mixture of 0.1 M NaOH + methanol (9:1). The developed method has been tested on the determination of DZ in a sample of commercial drug (Diazepam).

Rozsah stran

p. 285-291

ISSN

Trvalý odkaz na tento záznam

Projekt

Zdrojový dokument

Sensing in Electroanalysis. (K. Kalcher, R. Metelka, I. Švancara, K. Vytřas; Eds.). 2013/2014, Volume 8.

Vydavatelská verze

Přístup k e-verzi

open access

Název akce

ISBN

978-80-7395-782-7 (print)
978-80-7395-783-4 (pdf)

Studijní obor

Studijní program

Signatura tištěné verze

Umístění tištěné verze

Přístup k tištěné verzi

Klíčová slova

meniscus modified silver solid amalgam electrode, DC voltammetry, differential pulse voltammetry, Diazepam, determination

Endorsement

Review

item.page.supplemented

item.page.referenced