Bismuth-modified and the native tricresyl phosphate-based carbon paste electrode for the determination of two different pesticides
Článekpeer-reviewedpublishedDatum publikování
2012
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
Univerzita Pardubice
Abstrakt
In this article, the voltammetric responses of the bismuth powder bulk-modified tricresyl phosphate-based carbon paste electrode (Bi5%-C/TCP, where 5% is the content of pulverized metal), surface-modified, bismuth film-plated BiF-C/TCP), and the unmodified carbon paste electrode of the C/TCP type were studied and subsequently optimized for the cathodic determination of Imidacloprid (IMI), an insecticide reducible in a fairly negative
potential range. The individual comparisons have shown that the determination of IMI is more
efficient with the Bi5%-C/TCP or Bi20%-C/TCP, respectively, by the direct cathodic differential
pulse voltammetry (DPV). Concerning the determination of Carbendazim (CBZ), a fungicide
oxidizable at the positive potentials, the unmodified C/TCP was applied to the determination in the differential pulse anodic stripping voltammetric mode. The respective LODs were at the low μg mL-1 level for IMI or even down to the ng mL-1 for a more sensitive determination of CBZ.
Rozsah stran
p. 265-281
ISSN
Trvalý odkaz na tento záznam
Projekt
Zdrojový dokument
Sensing in Electroanalysis. (K. Kalcher, R. Metelka, I. Švancara, K. Vytřas; Eds.). 2012, Volume 7.
Vydavatelská verze
Přístup k e-verzi
open access
Název akce
ISBN
978-80-7395-563-2 (printed)
978-80-7395-564-9 (on-line)
978-80-7395-564-9 (on-line)
Studijní obor
Studijní program
Signatura tištěné verze
Umístění tištěné verze
Přístup k tištěné verzi
Klíčová slova
tricresyl phosphate-based carbon paste, two bismuth-modified variants, unmodifed form, voltammetric determination, imidacloprid (IMI), carbendazim (CBZ)