Determination of ascorbic acid using multi-wall carbon nanotubes immobilized on carbon paste electrode
ČlánekOtevřený přístuppeer-reviewedpublishedDatum publikování
2012
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
Univerzita Pardubice
Abstrakt
In this study, multi-wall carbon nanotubes (MWCNTs) immobilized on carbon paste electrode (CPE) was employed for the amperometric detection of ascorbic acid (AA). The influence of pH on the electrocatalytic effect of MWCNTs/CPE towards the oxidation of AA was studied; the effect of the potential applied and the stirring speed for amperometric detection of AA was investigated. The calibration curve was obtained for AA concentrations in a range of 1-100 μM. The detection limit for the method proposed was found to be 0.1 μM in the amperometric mode.
Rozsah stran
p. 301-309
ISSN
Trvalý odkaz na tento záznam
Projekt
Zdrojový dokument
Sensing in Electroanalysis. (K. Kalcher, R. Metelka, I. Švancara, K. Vytřas; Eds.). 2012, Volume 7.
Vydavatelská verze
Přístup k e-verzi
open access
Název akce
ISBN
978-80-7395-563-2 (printed)
978-80-7395-564-9 (on-line)
978-80-7395-564-9 (on-line)
Studijní obor