Publikace: Determination of amines using HPLC with fluorescence detection
Konferenční objektopen accesspeer-reviewedpublished| dc.contributor.author | Eisner, Aleš | cze |
| dc.contributor.author | Surmová, Silvie | cze |
| dc.contributor.author | Peterka, Ondřej | cze |
| dc.contributor.author | Bajerová, Petra | cze |
| dc.contributor.author | Bajer, Tomáš | cze |
| dc.contributor.author | Ventura, Karel | cze |
| dc.contributor.author | Adam, Martin | cze |
| dc.date.accessioned | 2019-05-22T08:50:01Z | |
| dc.date.available | 2019-05-22T08:50:01Z | |
| dc.date.issued | 2018 | eng |
| dc.description.abstract | A simple and sensitive method for the determination of free aliphatic and aromatic amines using derivatives agents (dansyl chloride, 9-fluorenylmethyl chloroformate and 4-Chloro-7-nitrobenzofurazan) as a labelling reagent by high-performance liq-uid chromatography with fluorescence detection (HPLC-FLD) has been developed. Derivatization conditions including reagent concentration, buffer pH, reaction time and temperature were optimized. A fluorescence derivatization - high-performance liquid chromatography (HPLC) method, which enables the femtomole-level detection of analytes, is a powerful tool for the analysis with high sensitivity and selectivity. In recent decades, improvised explosive devices (IEDs) have become an increasing topic of public concern, with high-profile incidents such as the Bali (2002), London transport (2005), Boston Marathon (2013) and Brussels (2016) bombings garnering mass international attention.[1] Although the majority of media coverage has fo-cused on large-scale incidents, there has also been a rise in explosive incidents in-volving smaller devices such as pipe bombs. This is particularly the case in the Unit-ed States, where pipe bombs are considered to make up the vast majority of IED en-counter. These devices can be easily constructed from everyday materials.[2] The mixture nitromethane with amines is applicable for this. Determination of resi-dues after an explosion is important. This method (HPLC-FLD) could be useful for their determination. The proposed method is sensitive and reproducible for the de-termination of aliphatic and aromatic amines. | eng |
| dc.description.abstract-translated | V práci je popsán vývoj metody pro stanovení alifatických aminů pomocí kapalinové chromatografie s využitím citlivé fluorescenční detekce. Je zde popsán způsob derivatizece. Nalezené podmínky byly testovány na reálných vzorcích, které byly získány po odpálení namíchaných směsí. | cze |
| dc.event | The 21st International Seminr New Trends in Research of Energetic Materials (18.04.2018 - 20.04.2018, Pardubice) | eng |
| dc.format | p. 533-537 | eng |
| dc.identifier.isbn | 978-80-7560-136-0 | eng |
| dc.identifier.obd | 39882055 | eng |
| dc.identifier.uri | https://hdl.handle.net/10195/72893 | |
| dc.language.iso | eng | eng |
| dc.peerreviewed | yes | eng |
| dc.publicationstatus | published | eng |
| dc.publisher | Univerzita Pardubice | eng |
| dc.relation.ispartof | Proceedings of the 21st Seminar on New Trends in Research of Energetic Materials | eng |
| dc.rights | open access | eng |
| dc.subject | amines | eng |
| dc.subject | HPLC | eng |
| dc.subject | derivatization | eng |
| dc.subject | aminy | cze |
| dc.subject | HPLC | cze |
| dc.subject | derivatizace | cze |
| dc.title | Determination of amines using HPLC with fluorescence detection | eng |
| dc.title.alternative | Stanovení aminů pomocí HPLC s fluorescenční detekcí | cze |
| dc.type | ConferenceObject | eng |
| dspace.entity.type | Publication |
Soubory
Původní svazek
1 - 1 z 1
Načítá se...
- Název:
- eisner.pdf
- Velikost:
- 255.81 KB
- Formát:
- Adobe Portable Document Format