Digitální knihovna UPCE přechází na novou verzi. Omluvte prosím případné komplikace. / The UPCE Digital Library is migrating to a new version. We apologize for any inconvenience.

Publikace:
Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode

Článekopen accesspeer-reviewedpostprint
dc.contributor.authorŠelešovská, Renátacze
dc.contributor.authorKränková, Barboracze
dc.contributor.authorŠtěpánková, Michaelacze
dc.contributor.authorKelíšková, Pavlínacze
dc.contributor.authorJaníková, Lenkacze
dc.contributor.authorChýlková, Jaromíracze
dc.contributor.authorNavrátil, Tomášcze
dc.date.accessioned2019-05-22T08:30:07Z
dc.date.available2019-05-22T08:30:07Z
dc.date.issued2018eng
dc.description.abstractMethod for voltammetric determination of leucovorin, a drug frequently applied to decrease some unfavorable effects of anticancer drugs such as methotrexate or to increase the therapeutic effect of 5-fluorouracil, has been developed employing a bare boron-doped diamond electrode. It is the first method for leucovorin determination based on its electrochemical oxidation. Although at least three anodic and three cathodic voltammetric peaks could be recorded under the used conditions, only the anodic response situated at about + 900 mV (vs. saturated Ag|AgCl electrode) was suitable, namely due to its shape and position, for analytical purposes. Using differential pulse voltammetry with optimized parameters and supporting electrolyte of pH 3.0, the linear dynamic range of leucovorin determination was recorded from 0.15 to 25 mu mol dm(-3). Under such conditions, low limit of quantification of 0.050 mu mol dm(-3) and limit of detection of 0.015 mu mol dm(-3) as well was reached. Relative standard deviation calculated from 11 repeated measurements amounted to 0.7% and calculated from five repeated determinations amounting less than 3.0%. Applicability of the developed method was verified by repeated analysis of the pharmaceutical preparation with excellent results (recovery 98.7-102.8%, relative standard deviation 1.81%).eng
dc.description.abstract-translatedByla vyvinuta voltametrická metoda stanovení léčiva leukovorinu s využitím borem dopované diamantové elektrody, která byla úspěšně aplikována při analýze vybraných farmaceutických přípravků.cze
dc.formatp. 1701-1708eng
dc.identifier.doi10.1007/s00706-018-2200-4eng
dc.identifier.issn0026-9247eng
dc.identifier.obd39881662eng
dc.identifier.scopus2-s2.0-85051284989
dc.identifier.urihttps://hdl.handle.net/10195/72721
dc.identifier.wos000442501400028eng
dc.language.isoengeng
dc.peerreviewedyeseng
dc.publicationstatuspostprinteng
dc.relation.ispartofMonatshefte fur Chemie, volume 149, issue: 9eng
dc.rightsembargoed accesseng
dc.subjectBoron-doped diamond electrodeeng
dc.subjectDeterminationeng
dc.subjectLeucovorineng
dc.subjectPharmaceutical sampleseng
dc.subjectVoltammetryeng
dc.subjectBorem dopovaná diamantová elektrodacze
dc.subjectStanovenícze
dc.subjectLeukovorincze
dc.subjectFarmaceutické vzorkycze
dc.subjectVoltametriecze
dc.titleVoltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrodeeng
dc.title.alternativeVoltametrické stanovení leukovorinu ve farmaceutických vzorcích s využitím borem dopované diamantové elektrodycze
dc.typeArticleeng
dspace.entity.typePublication

Soubory

Původní svazek

Nyní se zobrazuje 1 - 1 z 1
Načítá se...
Náhled
Název:
706_2018_2200_Author_poofs_bez_oprav.pdf
Velikost:
940.6 KB
Formát:
Adobe Portable Document Format
Popis: