Bismuth-modified and the native tricresyl phosphate-based carbon paste electrode for the determination of two different pesticides

Článekopen accesspeer-reviewedpublished
dc.contributor.authorĐorđević, Jelena
dc.contributor.authorRodić, Marko
dc.contributor.authorAshrafi, Amir
dc.contributor.authorPapp, Zsigmond
dc.contributor.authorGuzsvány, Valéria
dc.contributor.authorTrtić-Petrović, Tatjana
dc.contributor.authorŠvancara, Ivan
dc.contributor.authorVytřas, Karel
dc.date.accessioned2014-10-01T10:36:56Z
dc.date.available2014-10-01T10:36:56Z
dc.date.issued2012
dc.description.abstractIn this article, the voltammetric responses of the bismuth powder bulk-modified tricresyl phosphate-based carbon paste electrode (Bi5%-C/TCP, where 5% is the content of pulverized metal), surface-modified, bismuth film-plated BiF-C/TCP), and the unmodified carbon paste electrode of the C/TCP type were studied and subsequently optimized for the cathodic determination of Imidacloprid (IMI), an insecticide reducible in a fairly negative potential range. The individual comparisons have shown that the determination of IMI is more efficient with the Bi5%-C/TCP or Bi20%-C/TCP, respectively, by the direct cathodic differential pulse voltammetry (DPV). Concerning the determination of Carbendazim (CBZ), a fungicide oxidizable at the positive potentials, the unmodified C/TCP was applied to the determination in the differential pulse anodic stripping voltammetric mode. The respective LODs were at the low μg mL-1 level for IMI or even down to the ng mL-1 for a more sensitive determination of CBZ.eng
dc.formatp. 265-281eng
dc.identifier.isbn978-80-7395-563-2 (printed)
dc.identifier.isbn978-80-7395-564-9 (on-line)
dc.identifier.urihttps://hdl.handle.net/10195/58357
dc.language.isoeng
dc.peerreviewedyeseng
dc.publicationstatuspublishedeng
dc.publisherUniverzita Pardubice
dc.relation.ispartofSensing in Electroanalysis. (K. Kalcher, R. Metelka, I. Švancara, K. Vytřas; Eds.). 2012, Volume 7.eng
dc.rightsopen accesseng
dc.subjecttricresyl phosphate-based carbon pasteeng
dc.subjecttwo bismuth-modified variantseng
dc.subjectunmodifed formeng
dc.subjectvoltammetric determinationeng
dc.subjectimidacloprid (IMI)eng
dc.subjectcarbendazim (CBZ)eng
dc.titleBismuth-modified and the native tricresyl phosphate-based carbon paste electrode for the determination of two different pesticideseng
dc.typeArticle
dspace.entity.typePublication

Soubory

Původní svazek

Nyní se zobrazuje 1 - 1 z 1
Načítá se...
Náhled
Název:
DordevicJ_Bismuth-Modified_2012.pdf
Velikost:
446.7 KB
Formát:
Adobe Portable Document Format

Licence svazku

Nyní se zobrazuje 1 - 1 z 1
Načítá se...
Náhled
Název:
license.txt
Velikost:
1.71 KB
Formát:
Item-specific license agreed upon to submission
Popis: