Digitální knihovna UPCE přechází na novou verzi. Omluvte prosím případné komplikace. / The UPCE Digital Library is migrating to a new version. We apologize for any inconvenience.

Publikace:
Biosensors based on carbon paste electrodes using immobilized dehydrogenase enzymes. An overview and trends

Článekopen accesspeer-reviewedpublished
dc.contributor.authorLobo-Castañón, Maria Jesus
dc.contributor.authorAlvarez-Crespo, Suzana L.
dc.contributor.authorAlvarez-Gonzalez, Maria Isabel
dc.contributor.authorSaidman, Silvana B.
dc.contributor.authorMiranda-Ordieres, Arturo José
dc.contributor.authorTunon-Blanco, Paulino
dc.date.accessioned2021-02-22T11:29:04Z
dc.date.available2021-02-22T11:29:04Z
dc.date.issued1997
dc.description.abstractAmperometric biosensors based on two different NADH catalytic systems are presented. Common to both types is the design strategy which consists in the direct mixing of the NAD' -dependent dehydrogenase enzymes and other modifying molecules with the carbon paste combined with physical barriers like dialysis membranes or conducting polymers. One type is based on the use of a redox mediator (the phenothiazine dye Toluidine Blue O) to make possible the electrocatalytic oxidation of the enzymatically produced NADH at potentials close to 0 V. The second type is based on the use of the electrochemically generated conducting polymers poly(o-aminophenol) (PAP) and poly(o­phenylenediamine) (PPD), which allow not only the immobilization of enzyme and cofactor at the electrode surface but also the amperometric detection of NADH at potentials as low as 0 V without other immobilized electron transfer mediators. An ethanol biosensor based on the first catalytic system and ethanol, lactate and glutamate sensors based on the second one are presented.cze
dc.formatp. 17-29
dc.identifierUniverzitní knihovna (studovna)cze
dc.identifier.issn1211-5541
dc.identifier.signature47333-3
dc.identifier.urihttps://hdl.handle.net/10195/76832
dc.language.isoencze
dc.peerreviewedyeseng
dc.publicationstatuspublishedeng
dc.publisherUniverzita Pardubicecze
dc.relation.ispartofScientific papers of the University of Pardubice. Series A, Faculty of Chemical technology. 3(1997)eng
dc.rightsopen accesseng
dc.titleBiosensors based on carbon paste electrodes using immobilized dehydrogenase enzymes. An overview and trendscze
dc.typeArticlecze
dspace.entity.typePublication

Soubory

Původní svazek

Nyní se zobrazuje 1 - 1 z 1
Načítá se...
Náhled
Název:
S_17-29_Lobo-Castanon (Vol. 3).pdf
Velikost:
695.77 KB
Formát:
Adobe Portable Document Format
Popis: