Voltammetric determination of Diazepam at meniscus-modified silver solid amalgam electrode
ČlánekOtevřený přístuppeer-reviewedpublishedDatum publikování
2014
Autoři
Samiec, Petr
Fischer, Jan
Navrátilová, Zuzana
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
Univerzita Pardubice
Abstrakt
Voltammetric methods for determination of Diazepam (DZ) were developed. Techniques differential pulse voltammetry and DC voltammetry were used for determination of DZ at meniscus-modified silver solid amalgam electrode (m-AgSAE). The effect of the pH on the intensity of signal of DZ was studied in a mixture of Britton-Robinson buffer + methanol (9:1) and 0.1 M NaOH + methanol (9:1); the optimal medium for analysis was a mixture of 0.1 M NaOH + methanol (9:1). The developed method has been tested on the determination of DZ in a sample of commercial drug (Diazepam).
Rozsah stran
p. 285-291
ISSN
Trvalý odkaz na tento záznam
Projekt
Zdrojový dokument
Sensing in Electroanalysis. (K. Kalcher, R. Metelka, I. Švancara, K. Vytřas; Eds.). 2013/2014, Volume 8.
Vydavatelská verze
Přístup k e-verzi
open access
Název akce
ISBN
978-80-7395-782-7 (print)
978-80-7395-783-4 (pdf)
978-80-7395-783-4 (pdf)
Studijní obor
Studijní program
Signatura tištěné verze
Umístění tištěné verze
Přístup k tištěné verzi
Klíčová slova
meniscus modified silver solid amalgam electrode, DC voltammetry, differential pulse voltammetry, Diazepam, determination