dc.description.abstractA new procedure was elaborated to determine trace bismuth(III) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). The method is realized in highly acidic medium of hydrochloric acid in which antimony peak is negligible, and apparently catalyzed by presence of cadmium(II), thus allowing the determination at ppb levels. Calibration dependence was linear up to 110 ppb Bi with a detection limit (3 sigma) of 1.55 ppb. Applicability of the method was tested on the real sample of river water.eng
dc.description.abstract-translatedByl vypracován nový postup stanovení stopových množství bismutu(III) s využitím anodické rozpouštěcí voltametrie čtvercových vln na uhlíkové pastové elektrodě s antimonovým filmem (SbF-CPE). Měří se v silně kyselém prostředí kyseliny chlorovodíkové, v níž je rozpouštěcí pík antimonu sotva patrný, a využívá se zdánlivý katalytický efekt způsobený přítomností kadmia(II),l což dovoluje stanovení na úrovních jednotek ppb. Kalibrační závislost byla lineární až ke 100 ppb Bi s detekčním limitem (3) 1,55 ppb. Aplikovatelnost metody byla testována na reálném vzorku říční vodycze
dc.formatp. 68-76eng
dc.identifier.issn1452-3981
dc.identifier.obd39868275
dc.identifier.urihttps://hdl.handle.net/10195/66372
dc.identifier.wos000302723700006eng
dc.language.isoeng
dc.peerreviewedyeseng
dc.publicationstatuspostprinteng
dc.publisherElectrochemical Science Groupeng
dc.relation.ispartofInternational Journal of Electrochemical Science, volume 7, issue: 1eng
dc.rightsPouze v rámci univerzityeng
dc.subjectbismuth(III) determinationeng
dc.subjectstripping voltammetryeng
dc.subjectantimony film electrodeeng
dc.subjectcarbon paste electrodeeng
dc.subjectCd(II)-assisted catalysiseng
dc.subjectbismutcze
dc.subjectrozpouštěcí voltametriecze
dc.subjectantimonová filmová elektrodacze
dc.subjectuhlíková pastová elektroda, kadmium katalýzacze
dc.titleDetermination of Trace Bismuth(III) by Stripping Voltammetry at Antimony-Coated Carbon Paste Electrodeeng
dc.title.alternativeStanovení stopového množství bismutu s využitím anodické rozpouštěcí voltametrie na uhlíkové pastové elektrodě s antimonovým filmemcze
dc.typeArticleeng

Soubory

Původní svazek

Nyní se zobrazuje 1 - 1 z 1
Náhled není k dispozici
Název:
7010068.pdf
Velikost:
487.08 KB
Formát:
Adobe Portable Document Format