Determination of Trace Bismuth(III) by Stripping Voltammetry at Antimony-Coated Carbon Paste Electrode
ČlánekOmezený přístuppeer-reviewedpostprintdc.contributor.author | Ashrafi Amirmansoor | |
dc.contributor.author | Vytřas Karel | |
dc.date.accessioned | 2016-11-14T08:19:02Z | |
dc.date.available | 2016-11-14T08:19:02Z | |
dc.date.issued | 2012 | |
dc.description.abstract | A new procedure was elaborated to determine trace bismuth(III) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). The method is realized in highly acidic medium of hydrochloric acid in which antimony peak is negligible, and apparently catalyzed by presence of cadmium(II), thus allowing the determination at ppb levels. Calibration dependence was linear up to 110 ppb Bi with a detection limit (3 sigma) of 1.55 ppb. Applicability of the method was tested on the real sample of river water. | eng |
dc.description.abstract-translated | Byl vypracován nový postup stanovení stopových množství bismutu(III) s využitím anodické rozpouštěcí voltametrie čtvercových vln na uhlíkové pastové elektrodě s antimonovým filmem (SbF-CPE). Měří se v silně kyselém prostředí kyseliny chlorovodíkové, v níž je rozpouštěcí pík antimonu sotva patrný, a využívá se zdánlivý katalytický efekt způsobený přítomností kadmia(II),l což dovoluje stanovení na úrovních jednotek ppb. Kalibrační závislost byla lineární až ke 100 ppb Bi s detekčním limitem (3) 1,55 ppb. Aplikovatelnost metody byla testována na reálném vzorku říční vody | cze |
dc.format | p. 68-76 | eng |
dc.identifier.issn | 1452-3981 | |
dc.identifier.obd | 39868275 | |
dc.identifier.uri | https://hdl.handle.net/10195/66372 | |
dc.identifier.wos | 000302723700006 | eng |
dc.language.iso | eng | |
dc.peerreviewed | yes | eng |
dc.publicationstatus | postprint | eng |
dc.publisher | Electrochemical Science Group | eng |
dc.relation.ispartof | International Journal of Electrochemical Science, volume 7, issue: 1 | eng |
dc.rights | Pouze v rámci univerzity | eng |
dc.subject | bismuth(III) determination | eng |
dc.subject | stripping voltammetry | eng |
dc.subject | antimony film electrode | eng |
dc.subject | carbon paste electrode | eng |
dc.subject | Cd(II)-assisted catalysis | eng |
dc.subject | bismut | cze |
dc.subject | rozpouštěcí voltametrie | cze |
dc.subject | antimonová filmová elektroda | cze |
dc.subject | uhlíková pastová elektroda, kadmium katalýza | cze |
dc.title | Determination of Trace Bismuth(III) by Stripping Voltammetry at Antimony-Coated Carbon Paste Electrode | eng |
dc.title.alternative | Stanovení stopového množství bismutu s využitím anodické rozpouštěcí voltametrie na uhlíkové pastové elektrodě s antimonovým filmem | cze |
dc.type | Article | eng |
Soubory
Původní svazek
1 - 1 z 1
Náhled není k dispozici
- Název:
- 7010068.pdf
- Velikost:
- 487.08 KB
- Formát:
- Adobe Portable Document Format