dc.description.abstract |
Stanovenie F pomocou molekulárnej absorpcie monofluoridu gália (GaF) na rotačnej čiare 211.248 nm bolo optimalizované pomocou ContrAA 600 HR-CS-ETAAS. Spektrum elektrónovej excitácie GaF bolo získané v plynnej faze elektrotermického atomizátoru za vhodných experimentálnych podmienok po prídavku 100 g Ga na injekciu do grafitovej trubice ako molekulotvorného činidla s prídavkom zmesy chemického modifikátora 1,5 g Rh + 30 g CA. Týmto spôsobom sa mohla použiť maximálna teplota pyrolýzy 550 °C a optimálna teplota tvorby molekúl bola 1400 °C. Analyzovalo sa niekoľko vzoriek minerálnej vody a nápojov a jeden certifikovaný referenčný materiál (NIST SRM1566b Oyster Tissue). Výsledky boli v dobrej zhode s certifikovanou hodnotou. Detekčný limit a charakteristická hmotnosť metódy boli 7,2 g L -1 F a 0,19 ng F, v danom poradí. |
slo |
dc.format |
64 s.. |
|
dc.language.iso |
slo |
|
dc.publisher |
Univerzita Pardubice |
cze |
dc.rights |
Bez omezení |
|
dc.subject |
HR-CS-AAS |
slo |
dc.subject |
stanovenie fluóru |
slo |
dc.subject |
gallium mono fluorid |
slo |
dc.subject |
minerálna voda |
slo |
dc.subject |
nápoje |
slo |
dc.subject |
HR-CS-AAS |
eng |
dc.subject |
Fluorine determination |
eng |
dc.subject |
Gallium mono-fluoride |
eng |
dc.subject |
mineral water |
eng |
dc.subject |
beverage |
eng |
dc.title |
Stanovení fluoru vysokorozlišovací molekulovou absorpční spektrometrií s kontinuálním zdrojem záření (HR-CS-MAS) |
cze |
dc.title.alternative |
Determination of fluorine by high resolution-continuum source-molecular absorption spectrometry (HR-CS-MAS) |
eng |
dc.type |
diplomová práce |
cze |
dc.contributor.referee |
Mikysek, Tomáš |
|
dc.date.accepted |
2022-06-07 |
|
dc.description.abstract-translated |
The determination of F using the molecular absorption of gallium monofluoride (GaF) at the 211.248 nm rotational line has been optimized using the ContrAA 600 HR-CS-ETAAS. The electron excitation spectrum of GaF was generated by adding 100 g Ga per injection into the graphite tube as a molecule-forming reagent with the addition of a mixed chemical modifier 1.5 g Rh + 30 g CA. In this way a maximum pyrolysis temperature of 550° C could be used, and the optimal molecule formation temperature was 1400 ° C. Several mineral water samples and beverages and one certified reference material (NIST SRM1566b Oyster Tissue) were analyzed. The results were in good agreement with the certified value. The detection limit and the characteristic mass of the method were 7.2 ?g L -1 F and 0.19 ng F, respectively. |
eng |
dc.description.department |
Fakulta chemicko-technologická |
cze |
dc.thesis.degree-discipline |
Hodnocení a analýza potravin |
cze |
dc.thesis.degree-name |
Ing. |
|
dc.thesis.degree-grantor |
Univerzita Pardubice. Fakulta chemicko-technologická |
cze |
dc.thesis.degree-program |
Hodnocení a analýza potravin |
cze |
dc.description.defence |
Student seznámil členy zkušební komise s obsahem své diplomové práce, poté byl seznámen s posudky vedoucího a oponenta diplomové práce. Student odpověděl na otázky oponenta diplomové práce a členů zkušební komise. |
cze |
dc.identifier.stag |
44400 |
|
dc.description.grade |
Dokončená práce s úspěšnou obhajobou |
cze |