Advanced immunocapture of milk-borne Salmonella by microfluidic magnetically stabilized fluidized bed

Zobrazit minimální záznam

dc.contributor.author Srbová, Jana cze
dc.contributor.author Krulišová, Pavla cze
dc.contributor.author Holubová, Lucie cze
dc.contributor.author Pereiro, Iago cze
dc.contributor.author Bendali, Amel cze
dc.contributor.author Hamiot, Audrey cze
dc.contributor.author Podzemná, Veronika cze
dc.contributor.author Macák, Jan cze
dc.contributor.author Dupuy, Bruno cze
dc.contributor.author Descroix, Stephanie cze
dc.contributor.author Viovy, Jean-Louis cze
dc.contributor.author Bílková, Zuzana cze
dc.date.accessioned 2019-05-22T08:26:41Z
dc.date.available 2019-05-22T08:26:41Z
dc.date.issued 2018 eng
dc.identifier.issn 0173-0835 eng
dc.identifier.uri https://hdl.handle.net/10195/72692
dc.description.abstract The success of microfluidic immunocapture based on magnetic beads depends primarily on a sophisticated microscale separation system and on the quality of the magnetic immunosorbent. A microfluidic chip containing a magnetically stabilized fluidized bed (MSFB), developed for the capture and on-chip amplification of bacteria, was recently described by Pereiro etal.. The present work shows the thorough development of anti-Salmonella magnetic immunosorbents with the optimal capture efficiency and selectivity. Based on the corresponding ISO standards, these parameters have to be high enough to capture even a few cells of bacteria in a proper aliquot of sample, e.g. milk. The selection of specific anti-Salmonella IgG molecules and the conditions for covalent bonding were the key steps in preparing an immunosorbent of the desired quality. The protocol for immunocapturing was first thoroughly optimized and studied in a batchwise arrangement, and then the carrier was integrated into the MSFB chip. The combination of the unique design of the chip (guaranteeing the collision of cells with magnetic beads) with the advanced immunosorbent led to a Salmonella cell capture efficiency of up to 99%. These high values were achieved repeatedly even in samples of milk differing in fat content. The rate of nonspecific capture of Escherichia coli (i.e. the negative control) was only 2%. eng
dc.format p. 526-533 eng
dc.language.iso eng eng
dc.relation.ispartof Electrophoresis, volume 39, issue: 3 eng
dc.rights pouze v rámci univerzity eng
dc.subject Capture efficiency eng
dc.subject Immunomagnetic separation eng
dc.subject Microfluidic immunocapture eng
dc.subject Microfluidic magnetically stabilized fluidized bed eng
dc.subject Milk-borne bacteria eng
dc.subject účinnost záchytu cze
dc.subject imunomagnetická separace cze
dc.subject mikrofluidní imunospecifické vychytávání cze
dc.subject magnetem stabilizoavné mikrofluidní lože cze
dc.subject bakterie kontaminující mléko cze
dc.title Advanced immunocapture of milk-borne Salmonella by microfluidic magnetically stabilized fluidized bed eng
dc.title.alternative Imunospecifické vychytávání patogenních bakterií rodu Salmonella v mléce pomocí mikrofluidního systému s magnetem stabilizovaným fluidním ložem cze
dc.type article eng
dc.description.abstract-translated Účinnost vychytávání patogenních bakterií z mléka je silně závislá na kvalitě imunosorbentu, nosiči na bázi superparamagnetických částic, jejichž povrch je biofunkcionalizován specifickými protilátkami. MSFB systém - mikrofluidní separátor s integrovaným magnetem stabilizovaným fluidním ložem byl použit k izolaci a také k namnožení počtu patogenních bakterií pro další analýzu, např. PCR metodu pro průkaz bakteirální DNA. Selekttivita i specificita záchytu je klíčová pro praktické využití analyzátoru, je nutné dosáhnout parametrů, které vyžadují ISO standardy pro průkaz patogenů v potravinách. V práci je popsána biofunkcionalizace magnetických částic a jejich použití pro izolaci patogenů, buněk Salmonella sp. Sledovali jsme účinnost záchytu, výtěžnost, ale i specificitu záchytu, křížová reaktivita nebyla prokázána, míra nespecifické sorpce (směs Salmonella, E. coli) byla pouze 2%. cze
dc.peerreviewed yes eng
dc.publicationstatus published eng
dc.identifier.doi 10.1002/elps.201700257 eng
dc.identifier.wos 000424154000013 eng
dc.identifier.scopus 2-s2.0-85030450690
dc.identifier.obd 39882750 eng


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Vyhledávání


Rozšířené hledání

Procházet

Můj účet