Triclosan degradation by electro-Fenton process using electrolytic unit with titanium electrodes coated with mixed IrO2/RuO2

Zobrazit minimální záznam

dc.contributor.author Pérko, Jan cze
dc.contributor.author Hansen, Hans Christian Bruun cze
dc.contributor.author Weidlich, Tomáš cze
dc.date.accessioned 2018-02-27T03:50:04Z
dc.date.available 2018-02-27T03:50:04Z
dc.date.issued 2017 eng
dc.identifier.issn 1804-0195 eng
dc.identifier.uri https://hdl.handle.net/10195/70355
dc.description.abstract The paper focus on the degradation of a widely used antibacterial agent triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol) by electro-Fenton process. The electrochemical process was conducted in recirculating setup by passing the reaction mixture through an electrolytic unit consisting of titanium electrodes coated with mixed iridium and ruthenium oxides. An initial triclosan concentration of 10 mg/L was used throughout. Different reaction conditions and their impact on triclosan degradation were studied such as different concentrations of added iron(II) as Fenton reagent, different concentrations of sodium sulfate electrolyte, different flow rates, current density values and different pH values. High triclosan sorption to plastic surfaces of the equipment (tubing, cells etc) was observed and this phenomenon was quantified and taken into account during calculations. About 30 – 50% of triclosan was degraded after 80 minutes of electrolytic process. The optimum conditions for electro-Fenton degradation of triclosan were: current density 24 mA/cm2, flow rate 50 ml/min, pH 4, initial concentration of iron(II) at 5 mg/l, and 2 mmol/l sodium sulfate. eng
dc.format p. 116-124 eng
dc.language.iso eng eng
dc.relation.ispartof Waste Forum, volume 2017, issue: 3 eng
dc.rights open access eng
dc.subject Degradation eng
dc.subject electro-Fenton method eng
dc.subject triclosan eng
dc.subject advanced oxidation process eng
dc.subject degradace cze
dc.subject elektro-Fentonova oxidace cze
dc.subject triclosan cze
dc.subject pokročilé oxidační procesy cze
dc.title Triclosan degradation by electro-Fenton process using electrolytic unit with titanium electrodes coated with mixed IrO2/RuO2 eng
dc.title.alternative Degradace Triclosanu s použitím elektro-Fentonovy oxidace s použitím titanových elektrod potažených oxidy iridia a ruthenia cze
dc.type article eng
dc.description.abstract-translated Byla ověřena možnost odbourávání Triclosanu ve vodě při koncentraci 10 mg/l, přičemž dochází k odbourání 30 – 50% triclosanu po 80 minutách elektrochemické oxidace, nejlépe při proudové hustotě 24 mA/cm2, průtoku 50 ml/min, pH 4, a počáteční koncentraci železnatých iontů v roztoku 5 mg/l a koncentraci elektrolytu síranu sodného 2 mmol/l. cze
dc.peerreviewed yes eng
dc.publicationstatus postprint eng
dc.project.ID SGS_2017_002/Metody a postupy environmentálního inženýrství a hodnotového managementu eng