Comparison study of voltammetric determination of dantrolene using boron-doped diamond electrodes with different content of boron

Zobrazit minimální záznam

dc.contributor.author Martinková, Pavlína cze
dc.contributor.author Šelešovská, Renáta cze
dc.contributor.author Chýlková, Jaromíra cze
dc.contributor.author Behúl, Marián cze
dc.contributor.editor Navrátil, Tomáš cze
dc.contributor.editor Fojta, Miroslav cze
dc.contributor.editor Schwarzová, Karolína cze
dc.date.accessioned 2018-02-27T03:03:14Z
dc.date.available 2018-02-27T03:03:14Z
dc.date.issued 2017 cze
dc.identifier.isbn 978-80-905221-5-2 cze
dc.identifier.uri https://hdl.handle.net/10195/69990
dc.description.abstract Byly porovnávány elektrochemické vlastnosti borem dopovaných diamantových elektrod v závislosti na různém obsahu boru. Aplikační možnosti těchto elektrod byly ověřeny při stanovené dnatrolenu. cze
dc.format p. 142-146 cze
dc.language.iso cze cze
dc.publisher BEST Servis cze
dc.relation.ispartof XXXVII. Moderní elektrochemické metody : sborník přednášek cze
dc.rights open access cze
dc.subject Borem dopovaná diamantová elektroda cze
dc.subject voltametrie cze
dc.subject dantrolen cze
dc.subject porovnání cze
dc.subject Boron-doped diamond electrodes eng
dc.subject Voltammetry eng
dc.subject Dantrolene eng
dc.subject Comparison eng
dc.title Comparison study of voltammetric determination of dantrolene using boron-doped diamond electrodes with different content of boron cze
dc.title.alternative Comparison study of voltammetric determination of dantrolene using boron-doped diamond electrodes with different content of boron eng
dc.type ConferenceObject cze
dc.description.abstract-translated This study is focused on comparison of lab-made boron doped diamond electrodes (BDDE) with different content of boron prepared by hot filaments chemical vapor deposition. The set of electrodes with the range of B/C ratio in the gas phase from 2 000-20 000 ppm was tested. Their physical, chemical and electrochemical properties were investigated by using cyclic voltammetry with the redox markers [Fe(CN)6]3-/4- and [Ru(NH3)6]3+/2+. At the end, all BDDEs were applied for determination of drug dantrolene, to compare obtained statistical parameters and to find out as behavior of these electrodes exhibits some trends in relation to the boron content. eng
dc.event XXXVII. Moderní elektrochemické metody (15.05.2017 - 19.05.2017, Jetřichovice) cze
dc.peerreviewed yes cze
dc.publicationstatus postprint cze
dc.relation.publisherversion http://www.bestservis.eu/upload/file/Sbornik_metody17.pdf
dc.identifier.wos 000432424300031
dc.identifier.obd 39879463 cze


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Vyhledávání


Rozšířené hledání

Procházet

Můj účet