The effect of acetate buffer concentration on the anodic stripping voltammetric response of carbon paste (macro)electrodes and microelectrodes
ČlánekOtevřený přístuppeer-reviewedpublishedDatum publikování
2014
Vedoucí práce
Oponent
Název časopisu
Název svazku
Vydavatel
Univerzita Pardubice
Abstrakt
The Square Wave Anodic Stripping Voltammetry response of in situ deposited Bi-film conventional size Carbon Paste Electrodes (CPEs) and generic microdisc carbon paste microelectrodes (CPμEs) in Pb(II) and Cd(II) solutions, has been studied as a function of acetate buffer concentration in the extended 0.001 M -0.5 M range. The advantages of microelectrodes (high ohmic tolerance and high mass transfer rates) allowed for the recording of good quality voltammograms at the CPμEs even at the lowest 0.001 M acetate levels studied, resulted in relatively higher voltammetric peaks and gave an optimum Pb and Cd signal in the 0.01-0.02 M acetate range.
Rozsah stran
p. 171-182
ISSN
Trvalý odkaz na tento záznam
Projekt
Zdrojový dokument
Sensing in Electroanalysis. (K. Kalcher, R. Metelka, I. Švancara, K. Vytřas; Eds.). 2013/2014, Volume 8.
Vydavatelská verze
Přístup k e-verzi
open access
Název akce
ISBN
978-80-7395-782-7 (print)
978-80-7395-783-4 (pdf)
978-80-7395-783-4 (pdf)
Studijní obor
Studijní program
Signatura tištěné verze
Umístění tištěné verze
Přístup k tištěné verzi
Klíčová slova
anodic stripping voltammetry, carbon paste electrodes, microelectrodes