Applicability of antimony film electrodes in anodic stripping voltammetry combined with sequential injection analysis

Zobrazit minimální záznam

dc.contributor.author Guzsvány, Valéria
dc.contributor.author Nakajima, Hizuru
dc.contributor.author Soh, Nobuaki
dc.contributor.author Nakano, Koji
dc.contributor.author Švancara, Ivan
dc.contributor.author Imato, Toshimiko
dc.date.accessioned 2012-03-14T13:50:17Z
dc.date.available 2012-03-14T13:50:17Z
dc.date.issued 2010
dc.identifier Univerzitní knihovna (studovna)
dc.identifier.isbn 978-80-7395-386-7 (Online)
dc.identifier.isbn 978-80-7395-368-3 (Print)
dc.identifier.issn 1211-5541
dc.identifier.uri http://hdl.handle.net/10195/42629
dc.description.abstract The possibilities to employ antimony-film plated glassy carbon electrode (SbFGCE) in anodic stripping voltammetry combined with sequential injection analysis(ASV-SIA) were examined and tested for the determination of Pb(II) and Cd(II) selected as the model ions. It has been found that SbF-GCE can be operated at the low :g l–1 concentration level via the in-situ preparation — deposition from a plating solution of 0.5 M HCl, mixed with 0.75 mg l–1 Sb(III), and at a potential of –1.5 V vs. Ag/AgCl. The same solution could then be used for pre-concentration and stripping, when the reproducibility of the respective signals was characterised 20 Guzsvány V. et al./Sci. Pap. Univ. Pardubice Ser. A 16 (2010) 19–31 by means of the RSD < 2.8 %, and the detection limit (3F) of about 1.2 μg l–1 Pb(II) and 1.4 μg l-–1 Cd(II). Furthermore, as found, the presence of weakly complexing halide salts, KCl or KBr, could further improve the overall signal-tonoise ratio, whereas the addition of KSCN into the solution(s) offered the possibility to detect some additional ions; namely, of highly electronegative metal elements such as Zn(II), Mn(II), and Cr(III). eng
dc.format p. 19-31
dc.language.iso eng
dc.publisher Univerzita Pardubice cze
dc.relation.ispartof Scientific papers of the University of Pardubice. Series A, Faculty of Chemical Technology. 16 (2010)
dc.subject antimony film eng
dc.subject anodic stripping voltammetry eng
dc.subject sequential injection analysis eng
dc.title Applicability of antimony film electrodes in anodic stripping voltammetry combined with sequential injection analysis eng
dc.type Article eng
dc.identifier.signature 47333-16
dc.peerreviewed yes
dc.publicationstatus published